The connection succeeded, but required services (for example RPC) are missing on the target.
Check firewalls and target health. For Windows, confirm access to WMI, Remote Registry, RPC, and the SMB (C$) share.
Scan Completion Issues
Status
Cause
Action
PartialScan
Connected with sufficient privileges and a trustable identifier, but some data (disks, filesystems, processes, connections) wasn’t collected. Application scan failures can also cause this.
Check logs for the specific step that failed.
ScanFailure
An unrecoverable or unexpected error, an untrustable identifier, missing key configuration items, or a timed-out/aborted scan.
Check logs.
ConnectionFailed
An unexpected connection error, distinct from a credential or privilege failure.
Check logs.
Aborted
The scan was aborted.
Check logs.
NoResult
No scan result was received for this target.
Check logs.
Unknown
An unexpected condition occurred.
Check logs.
Skipped Targets
Status
Cause
SkippedAsSameAs
This target was already scanned in the same scan job via a different IP.
SkippedAsExcluded
The target is in an exclusion scope for this scan job.
SkippedAsWorkStation
The target’s OS was identified as a workstation edition.
Skipped targets require no action.
Diagnosing a Specific Target
For deeper detail on any target, open its Scan Info link in the Scan Status view. Common diagnostic messages include:
Message
Meaning
Action
Failed to gather process connections
An OS command couldn’t list local-to-remote process connections, used for dependency mapping.
Check the credential’s permission to run netstat on *nix machines.
Truncated process command line
The OS limited how much of a process’s command line could be returned, so the executable couldn’t be fully identified.
No action — this is an OS limitation.
dmidecode command not available
The scan couldn’t uniquely identify the server without this command.
Check the credential’s permission to run dmidecode; install the package if it’s optional on that OS.
Failed to gather identifier
No available command could establish a unique identifier for the target.
Check the credential’s permissions for identity commands; contact support to identify which command is failing.
SELECT SERIALNUMBER FROM Win32_BIOS failed
The WMI command used to uniquely identify the server didn’t return a result.
Check the credential’s permission to run this command over WMI.